3.3.17. TCP Server Application: Multiple TCP Connections
To have more than one TCP Client connecting to SE5001A in TCP Server mode, contact Atop Technical Support to
obtain a special multi-connection version firmware. After the firmware is uploaded to SE5001A, the WebUI will have
one additional option called Multiple_Connections(Figure 3.32). The Multi-Connection option will allow up to a
maximum of four TCP Client connections. SE5001A will broadcast serial data to all connected TCP Clients. Note
that it is also possible to use this multi-connection feature in conjunction with other TCP Server applications, such as
Virtual COM, Pair Connection, and Reverse Telnet. For example, enabling multi-connection along with Pair
connection will result in Multi-Point Pair Connection in TCP mode (section 3.3.18).
Figure 3.32 TCP Server with Multiple Connections Enabled