5.2.6 TCP Client Application: Configure SW550xC as a Pair
Connection Slave
A Pair Connection Slave, is shown in Figure 5.14; it is necessary to pair up with a Pair
Connection Master. Please setup a Pair Connection Master first before proceeding.
Figure 5.14
Follow Sec. 5.1.2 to configure SW550xC in TCP Client mode properly.
Click on the dropdown box of the Application option and switch to “Pair Connection
Slave” to enabled Pair Connection application in SW550xC.
Match the Destination IP with the settings of Pair Connection Master’s IP that was
setup previously.
Scroll to the bottom of the page and click on Save & Apply button to save the
changes.