Atop Serial Device Server
SE5002D
User Manual V. 1.1
3.3.2 Networking Setup
Configure IP, SNMP, and alert settings on this page. Please fill in the IP information in the fields
under the TCP/IP header. Alternatively, enable DHCP to obtain IP address, gateway and
subnet mask from DHCP server automatically, Fig. 3. 19.
Fig. 3. 19
Enable SNMP and Alert Events by checking Enable, Fig. 3. 20. Fill in SNMP information in
the fields under the SNMP header. Enable different Alert Events to send these events to a
SNMP Trap Server.
Cold/Warm Start
Triggers when the device is rebooted from the application level or physical level.
Link Down
Triggers when the TCP connection of the designated COM port is closed.
Link Up
Triggers when the TCP connection of the designated COM port is established.
Authentication Failure
Triggers when the username/password entered in the Telnet console or the WebUI is
incorrect.